MTR Corporation says it will take firm action against the main contractor at the under-construction Tung Chung West station after roughly 30 concrete pillars at the platform level were found not to have been fully filled with concrete during pouring.

The corporation said it issued a non-conformance notice to the contractor under the works contract and quality control standards, and is following up on the failures, handling procedures and responsibility. It is awaiting the contractor’s comprehensive report and proposed rectification plan before deciding further action.

The problem surfaced during a routine inspection in October of unfinished works, when MTR found that the top ends of some platform-level pillars had undergone material patching repairs without prior approval. The corporation said it immediately instructed the main contractor to stop the works and launched an in-depth investigation. TVB reported that the contractor was suspended and must submit a rectification plan and full report before work can resume.

The Buildings Department said it first noticed the issue on October 27 during a regular inspection and quality audit, finding two defective columns, and ordered the registered structural engineer and contractor to conduct a comprehensive check. As of last Friday, the engineer had identified around 30 defective concrete pillars at the site, the department said.

The department said the defects pose no immediate danger. Because the station is built using the top-down method — floor slabs cast before columns and walls — the temporary falsework supporting the floor slab has not yet been removed, so the defective columns do not threaten the station’s structural integrity. The department also said the project’s registered structural engineer was not required to report the situation immediately under the Code of Practice for Site Supervision, but has been required to submit an investigation report and proposed remedial measures by mid-November.

MTR said it attaches great importance to supervision and quality on railway projects, will continue inspections and other supervisory measures, and will maintain close communication with government departments. It said it will fully cooperate with the government’s investigation and submit timely reports on the root cause, remedial measures and follow-up actions against the contractor, adding that it does not tolerate substandard work practices.

The reports followed an exclusive by HK01 on Saturday, that around 30 pillars in the station’s concourse were suspected of being improperly poured, leaving gaps of roughly 20 to 30 centimetres between the concrete and the ceiling. HK01 reported that about half of the roughly 60 pillars on the concourse level showed similar defects. MTR confirmed problematic columns on the platform level but did not confirm whether the concourse level is also affected, saying only that it was checking all concrete pillars on both levels.

Chan Sai-cheong, a former chairman of the Hong Kong Institution of Engineers, said a gap between the top of a pillar and the ceiling is normally left during construction and filled with concrete only after floor work is completed — suggesting the defects may reflect work still in progress. Chau Sze-kit, chairman of the Hong Kong Construction Industry Employees General Union, questioned the construction method, said the contractor should have reported changes to MTR before carrying out repairs, and joined Chan in calling on MTR to release more details.

The station, a three-storey structure with ground, concourse and platform levels, is set for completion by 2029. Whether the contractor’s report and the engineer’s mid-November submission identify the cause — and what action MTR ultimately takes — remains to be seen.